How to solve common malfunctions in Concrete Batching Plant?
01 16,2026
Concrete Batching Plants often experience six types of malfunctions during operation due to aging and wear of components and environmental factors. What are the methods for troubleshooting concrete mixing plant failures? How to solve common problems? Please see the introduction below.

- Inaccurate Cement Scale Weighing
This malfunction is characterized by the scale displaying the correct value after calibration with weights, but the reading does not return to zero after unloading. After zeroing, the reading changes significantly when weights are added again, but the sensor resistance value is within the normal range, and the instrument is functioning correctly.
Possible causes include: the angle iron used to fix the scale frame during transportation has not been removed; the pressure head and pressure plate are stuck; the scale body interferes with external objects; the three sensors are not of the same model; and the weighing material is unevenly distributed.
The methods for troubleshooting this Concrete Batching Plant malfunction are: If the angle iron used to fix the scale frame during transportation has not been removed, it should be removed promptly; if the pressure head or pressure plate is stuck, it should be dealt with promptly to ensure smooth movement without resistance; if the scale body interferes with external objects, it should be isolated promptly; if the three sensors are not of the same model, replace them with sensors of the same model; if the material is unevenly distributed, adjust it. - Difficulty Opening and Closing the Aggregate Bin Discharge Gate When Empty
This malfunction is characterized by slow and weak cylinder movement, but inspection shows no friction or jamming in the mechanical part of the discharge gate, and there is no air leakage in the solenoid valve or cylinder.
Possible causes include: obstructed air path, such as a dirty filter element in the air-water separator of the three-way valve at the air source, causing an obstructed air path and reducing the gas flow rate per unit time, thus causing slow cylinder movement; a dirty muffler, resulting in a smaller pressure difference between the rod chamber and the non-rod chamber during cylinder movement, leading to slow cylinder movement.
The methods for troubleshooting this Concrete Batching Plant malfunction are: If the air path is obstructed, clean or replace the filter element promptly; if the muffler is dirty, clean the muffler promptly. - No Material Discharge from the Discharge Port
This malfunction is characterized by no material discharge from the discharge port of the screw conveyor when the contactor is engaged and the motor rotates clockwise. After a short time, the circuit breaker trips; after resetting the circuit breaker and starting the motor, it still trips, and no solidification of the powder material is observed. Possible causes for the problem include: the main motor is rotating in reverse; the circuit breaker is damaged; or there may be a poor connection in one phase of the main motor wiring.
The method for troubleshooting concrete mixing plant failures is: If the main motor is rotating in reverse, simply swap any two of the main motor’s wiring connections; if the circuit breaker is damaged, it should be replaced; if there is a poor connection in one phase of the main motor wiring, it should be inspected and repaired. - Mixer shaft “stalling”
This fault manifests as the mixer shaft rotating with difficulty or even stopping completely when the main mixer is mixing mortar.
Possible causes include: severe overload, material jamming the shaft; human error causing secondary feeding; inaccurate weighing; large gap between the mixing blades or side blades and the inner wall of the tank, with foreign objects getting stuck in between; low voltage; incorrect mixing parameter settings.
The method for troubleshooting Concrete Batching Plant failures is: If there is severe overload and material is jamming the shaft, the mixing capacity should be adjusted and solidified mortar should be cleaned promptly; if human error causes secondary feeding, the excess material should be removed and the process should be followed according to the process flow; if the weighing is inaccurate, the operator should recalibrate the scale; if there are foreign objects stuck between the mixing blades or side blades and the inner wall of the tank, the gap between the blades and the liner should be adjusted to be no more than 5 mm, and the foreign objects should be removed promptly; if the voltage is too low, the line voltage should be checked again; if the parameters are set incorrectly, the corresponding batching data should be carefully checked and corrected in time. - Main mixer discharge gate cannot open
This fault manifests as the main mixer discharge gate not opening when the mixing plant is working automatically, and the discharge indicator light not illuminating when mixing is complete.
Possible causes include: foreign objects or accumulated material between the discharge gate and the sealing plate; insufficient pressure in the pneumatic system, leakage in the cylinder or damage to the oil mist lubricator; loose or poor connection between the solenoid valve and the relay, or damage to the relay; burnt out solenoid valve coil or stuck valve core; damaged time relay, resulting in no normal input signal to the PLC. The methods for troubleshooting Concrete Batching Plant malfunctions are as follows: If there are foreign objects or accumulated material between the discharge gate and the sealing plate, the foreign objects and accumulated material should be cleaned and the discharge gate should be flushed; if the pneumatic system pressure is insufficient, there is leakage in the cylinder, or the oil mist lubricator is damaged, the oil mist lubricator, connectors, and cylinder should be checked for damage; if the wiring between the solenoid valve and the relay is loose, poorly connected, or the relay is damaged, the relay contact output and wiring should be checked, and replaced if necessary; if the solenoid valve coil is burned out or the valve core is stuck, the solenoid valve should be replaced; if the time relay is damaged, it should be replaced. - Conveyor Belt Misalignment
This malfunction manifests in three situations: First, the conveyor belt deviates to the same side under both no-load and loaded conditions, meaning the conveyor belt centerline deviates laterally, and the conveyor belt deviates towards the side with less material; second, the conveyor belt deviates left and right without a fixed direction; third, the conveyor belt deviates in the middle of the entire conveyor system.
Uneven foundation, material sticking to the idler rollers, unbalanced trough rollers, and unbalanced adjustment of the driving and driven rollers can all cause conveyor belt misalignment. If the conveyor belt deviates to the same side under both no-load and loaded conditions, it indicates that the tension on both sides of the conveyor belt is uneven or the frame is uneven. In this case, the frame foundation should be leveled first, the material sticking to the idler rollers should be removed, and the tensioning mechanism screw or counterweight should be adjusted. If the conveyor belt deviates left and right without a fixed direction, it indicates that the conveyor belt is loose, and the tensioning mechanism should be adjusted. If the conveyor belt deviates in the middle of the conveyor, it can be corrected by adjusting the position of the idler roller group.
Adjustment method: If the conveyor belt deviates to one side, the idler roller group on that side should be moved laterally in the direction of the conveyor belt’s movement, or the idler roller group on the other side can be moved backward (or the idler roller bracket on the other side can be appropriately raised). The adjustment method for the return idler roller group is the same as for the carrying idler roller group. For longer conveyor belt systems, adjusting the idler roller group is very effective. Adjusting the redirecting roller is a crucial step in correcting conveyor belt misalignment. The roller’s installation position must be perpendicular to the centerline of the conveyor’s material flow direction; otherwise, misalignment will inevitably occur. If the conveyor belt deviates to the right side of the roller, the right-side bearing housing should be moved forward (or the left-side bearing housing moved backward); if the conveyor belt deviates to the left side of the roller, the left-side bearing housing should be moved forward (or the right-side bearing housing moved backward).
If the conveyor belt is misaligned relative to the driven roller, the adjustment method is the opposite of that for the driving roller.
Related Information
How much does a horizontal cement tank cost?
What are the specifications of the HZS120 Concrete Batching Plant?
How to resolve errors in the weighing system of the WBZ600T stabilized soil mixing plant?
How good are mobile soil stabilization mixing plants?
How much does it cost to invest in a water-stabilized mixing plant?